Liu Gao as a in the 10KV Amorphous Alloy Dry Type Transformer Manufacturers, Dry type Transformer in compliance with the IEC726 and GB/T10228-1997 standards, is characterized by its impressive array of attributes. These include not only low loss, compact and lightweight construction but also a minimal noise level, damp-proofing, high mechanical strength, flame resistance, robust overload capacity, and a low level of partial discharge. These transformers find broad applicability in power transmission and distribution systems, particularly in heavy load centers and locations with stringent fire protection requirements, making them a versatile and reliable choice for diverse operational environments.

Send Inquiry

Product Description

Liu Gao is a 10KV Amorphous Alloy Dry Type Transformer Suppliers,The Non-encapsulated coil dry type transformer stands out for its multifaceted qualities, placing a strong emphasis on safety, reliability, energy efficiency, fire protection, and anti-explosion features, coupled with the added advantage of simple maintenance. The dry type transformer's efficacy is further enhanced by a meticulously designed coil structure and a vacuum impregnation treatment process, ensuring immunity to partial discharge and preventing any decline in insulation levels throughout its entire shelf life. Rigorous qualification processes by both the National Mechanical & Industrial Bureau and the National Power Company underscore the dry type transformer's compliance with national standards.


This dry type transformer proves highly adaptable to demanding environments characterized by stringent fireproofing requirements, fluctuating loads, lack of ventilation, confined spaces, dirt, and moisture. Its versatility extends to diverse settings such as power plant fields, subway systems, metallurgical facilities, hospitals, high-rise buildings, shipping centers, crowded residential zones, and specialized environments like petrochemical industries, nuclear power stations, and nuclear submarines. Specifically, in power plant fields, the Non-encapsulated coil dry type transformer plays a crucial role in maintaining safety, reliability, and energy efficiency, making it an indispensable component in the station's infrastructure. The dry type transformer's robust design and comprehensive features make it an ideal solution for addressing the unique challenges posed by a variety of operational scenarios, contributing to the overall efficiency and safety of the power station.

10KV Amorphous Alloy Dry Type Transformer Operating Environment

1.The height above the sea level is below 1000m.

2.Highest air temperature +40ºC

3.Highest daily average air temperature +30ºC

4.Highest annual average air temperature+20v

5.Lowest outdoor air temperature-25ºC

6. Installation location: suitable for installation in areas free from fire or explosion hazards, significant pollution, chemical corrosion, or excessive vibration, whether indoors or outdoors.

10KV Amorphous Alloy Dry Type Transformer Characteristics

1.Operate within specified limits: +40ºC (highest air temperature), +30ºC (highest daily average), and +20ºC (highest annual average).

2.Suitable for Dry type transformers at altitudes below 1000m. Consider extremes: -25ºC (lowest outdoor temperature).

Ventilation:

3.Adequate airflow is essential for Dry type transformers to dissipate heat.

4.Dry type transformers are resistant to moisture; protect from prolonged exposure to high humidity.

5.Dry type transformers should operate within specified load and voltage limits.

6.Implement protection measures against harmonics and voltage fluctuations.

7.Install Dry type transformers in areas free from fire/explosion hazards, pollution, corrosion, or excessive vibration, whether indoors or outdoors.

8.Adhere to regular maintenance practices per the manufacturer's recommendations.

9.Dry type transformers should operate within their specified overload capacity.

10.Maintain low noise levels in Dry type transformers.

10KV Amorphous Alloy Dry Type Transformer Specification

Technical data of 11KV SCBH15 series resin insulation dry type transformer
KVA Voltage VECTOR Impedance voltage LOSSES (W) No-load Current
GROUP (%) (%)
HV LV No-load loss Load loss
(kV) (V)
200 6 380 Yyn0 4 200 2530 0.9
6.3 400 Dyn11
10 415 Yzn11
10.5 433
11
13.2
250 230 2755 0.8
315 280 3470 0.8
400 310 3990 0.7
500 360 4880 0.6
630 6 410 5960 0.6
800 480 6950 0.5
1000 550 8130 0.5
1250 650 9690 0.5
1600 760 11730 0.4
2000 1000 14450 0.4
2500 1200 17170 0.3

Product Features

Factory Shoot

Packaging

Hot Tags: 10KV Amorphous Alloy Dry Type Transformer, China, Manufacturers, Suppliers, Factory, Quality, Customized